LC1D09F7 | TeSys D Contactor, 3-Poles (3 NO), 9A, 110V AC Coil, Non-Reversing | Schneider Electric (Square D)
$142.52
Get your Special Pricing!
Log In / Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Schneider Electric (Square D)SKU: LC1D09F7
List Price
$428.00
$142.52
Availability: This product is currently available to purchase
Contact us for price breaks on large quantities!
Orders over $999 ship FREE*
The product is not cancelable or returnable unless found defective
*Free shipping applies within the continental US and weighing less than 50 lbs.
Shipping and Returns Terms

Speak With a Technical Expert

Call (847) 773-1023

Hours: 9am - 5pm CDT M-F

LC1D09F7 | TeSys D Contactor, 3-Poles (3 NO), 9A, 110V AC Coil, Non-Reversing | Schneider Electric (Square D)

Schneider Electric (Square D) | LC1D09F7
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LC1D09F7

Overview

Details for LC1D09F7

LC1D09F7 Contactor: Durable and Efficient Protection for Industrial Applications. The Schneider Electric (Square D) LC1D09F7 Contactor is a high-quality electromechanical device designed to control and protect electrical circuits in industrial environments. This compact contactor features: - Reliable performance with a long mechanical and electrical life - 3-pole design for controlling three-phase power systems - 25A current rating, suitable for a wide range of applications - 110V AC operating voltage, compatible with common industrial power systems - Finger-safe terminals for added safety during installation and maintenance - Clear markings for easy identification and wiring. With its durability, reliability, and ease of use, the LC1D09F7 Contactor is an excellent choice for industrial engineers and maintenance professionals. Our HVAC supply store offers the best prices and fast shipping - get yours today! TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 9A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200-208VAC, 25HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 25A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.71 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
Range of Product
TeSys Deca
Product or Component Type
Contactor
device short name
LC1D
contactor application
Resistive load;Motor control
utilisation category
AC-1;AC-3;AC-4;AC-3e
poles description
3P
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz;Power circuit <= 300 V DC
[Ie] rated operational current
9 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit;25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit;9 A 140 °F (60 °C)) <= 440 V AC AC-3e power circuit
[Uc] control circuit voltage
110 V AC 50/60 Hz
motor power kW
2.2 kW 220...230 V AC 50/60 Hz AC-3);4 kW 380...400 V AC 50/60 Hz AC-3);4 kW 415...440 V AC 50/60 Hz AC-3);5.5 kW 500 V AC 50/60 Hz AC-3);5.5 kW 660...690 V AC 50/60 Hz AC-3);2.2 kW 400 V AC 50/60 Hz AC-4);2.2 kW 220...230 V AC 50/60 Hz AC-3e);4 kW 380...400 V AC 50/60 Hz AC-3e);4 kW 415...440 V AC 50/60 Hz AC-3e);5.5 kW 500 V AC 50/60 Hz AC-3e);5.5 kW 660...690 V AC 50/60 Hz AC-3e)
Maximum Horse Power Rating
1 hp 230/240 V at AC 50/60 Hz for 1 phase;2 hp 200/208 V at AC 50/60 Hz for 3 phase;2 hp 230/240 V at AC 50/60 Hz for 3 phase;5 hp 460/480 V at AC 50/60 Hz for 3 phase;7.5 hp 575/600 V at AC 50/60 Hz for 3 phase;0.33 hp 115 V at AC 50/60 Hz for 1 phase
compatibility code
LC1D
pole contact composition
3 NO
contact compatibility
M2
protective cover
With
[Ith] conventional free air thermal current
25 A 140 °F (60 °C) power circuit;10 A 140 °F (60 °C) signalling circuit
Irms rated making capacity
250 A 440 V power circuit IEC 60947;140 A AC signalling circuit IEC 60947-5-1;250 A DC signalling circuit IEC 60947-5-1
rated breaking capacity
250 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
105 A 104 °F (40 °C) - 10 s power circuit;210 A 104 °F (40 °C) - 1 s power circuit;30 A 104 °F (40 °C) - 10 min power circuit;61 A 104 °F (40 °C) - 1 min power circuit;100 A - 1 s signalling circuit;120 A - 500 ms signalling circuit;140 A - 100 ms signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1;25 A gG <= 690 V type 1 power circuit;20 A gG <= 690 V type 2 power circuit
average impedance
2.5 mOhm - Ith 25 A 50 Hz power circuit
power dissipation per pole
1.56 W AC-1;0.2 W AC-3;0.2 W AC-3e
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1;Power circuit 600 V CSA;Power circuit 600 V UL;Signalling circuit 690 V IEC 60947-1;Signalling circuit 600 V CSA;Signalling circuit 600 V UL
overvoltage category
III
pollution degree
3
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability
15 Mcycles
electrical durability
0.6 Mcycles 25 A AC-1 <= 440 V;2 Mcycles 9 A AC-3 <= 440 V;2 Mcycles 9 A AC-3e <= 440 V
control circuit type
AC 50/60 Hz standard
coil technology
Without built-in suppressor module
control circuit voltage limits
0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz;0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz;0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz;1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
inrush power in VA
70 VA 60 Hz 0.75 68 °F (20 °C));70 VA 50 Hz 0.75 68 °F (20 °C))
hold-in power consumption in VA
7.5 VA 60 Hz 0.3 68 °F (20 °C));7 VA 50 Hz 0.3 68 °F (20 °C))
heat dissipation
2…3 W 50/60 Hz
operating time
12...22 ms closing;4...19 ms opening
maximum operating rate
3600 cyc/h 140 °F (60 °C)
connections - terminals
Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end;Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end;Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end;Power circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end;Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end;Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end
tightening torque
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm;Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2;Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
auxiliary contact composition
1 NO + 1 NC
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1;Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency
25...400 Hz
minimum switching voltage
17 V signalling circuit
minimum switching current
5 mA signalling circuit
insulation resistance
> 10 MOhm signalling circuit
non-overlap time
1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact
Mounting Support
Plate;Rail
standards
CSA C22.2 No 14;EN 60947-4-1;EN 60947-5-1;IEC 60947-4-1;IEC 60947-5-1;UL 508;IEC 60335-1
Product Certifications
UL;GOST;GL;CCC;BV;LROS (Lloyds register of shipping);CSA;DNV;RINA;UKCA
IP degree of protection
IP20 front face IEC 60529
protective treatment
THIEC 60068-2-30
climatic withstand
IACS E10 exposure to damp heat;IEC 60947-1 Annex Q category D exposure to damp heat
permi

Specifications

Item Number
LC1D09F7
Brand
Schneider Electric (Square D)
Brand
Square D
Range of Product
TeSys Deca
Product or Component Type
Contactor
device short name
LC1D
contactor application
Resistive load;Motor control
utilisation category
AC-1;AC-3;AC-4;AC-3e
poles description
3P
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz;Power circuit <= 300 V DC
[Ie] rated operational current
9 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit;25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit;9 A 140 °F (60 °C)) <= 440 V AC AC-3e power circuit
[Uc] control circuit voltage
110 V AC 50/60 Hz
motor power kW
2.2 kW 220...230 V AC 50/60 Hz AC-3);4 kW 380...400 V AC 50/60 Hz AC-3);4 kW 415...440 V AC 50/60 Hz AC-3);5.5 kW 500 V AC 50/60 Hz AC-3);5.5 kW 660...690 V AC 50/60 Hz AC-3);2.2 kW 400 V AC 50/60 Hz AC-4);2.2 kW 220...230 V AC 50/60 Hz AC-3e);4 kW 380...400 V AC 50/60 Hz AC-3e);4 kW 415...440 V AC 50/60 Hz AC-3e);5.5 kW 500 V AC 50/60 Hz AC-3e);5.5 kW 660...690 V AC 50/60 Hz AC-3e)
Maximum Horse Power Rating
1 hp 230/240 V at AC 50/60 Hz for 1 phase;2 hp 200/208 V at AC 50/60 Hz for 3 phase;2 hp 230/240 V at AC 50/60 Hz for 3 phase;5 hp 460/480 V at AC 50/60 Hz for 3 phase;7.5 hp 575/600 V at AC 50/60 Hz for 3 phase;0.33 hp 115 V at AC 50/60 Hz for 1 phase
compatibility code
LC1D
pole contact composition
3 NO
contact compatibility
M2
protective cover
With
[Ith] conventional free air thermal current
25 A 140 °F (60 °C) power circuit;10 A 140 °F (60 °C) signalling circuit
Irms rated making capacity
250 A 440 V power circuit IEC 60947;140 A AC signalling circuit IEC 60947-5-1;250 A DC signalling circuit IEC 60947-5-1
rated breaking capacity
250 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
105 A 104 °F (40 °C) - 10 s power circuit;210 A 104 °F (40 °C) - 1 s power circuit;30 A 104 °F (40 °C) - 10 min power circuit;61 A 104 °F (40 °C) - 1 min power circuit;100 A - 1 s signalling circuit;120 A - 500 ms signalling circuit;140 A - 100 ms signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1;25 A gG <= 690 V type 1 power circuit;20 A gG <= 690 V type 2 power circuit
average impedance
2.5 mOhm - Ith 25 A 50 Hz power circuit
power dissipation per pole
1.56 W AC-1;0.2 W AC-3;0.2 W AC-3e
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1;Power circuit 600 V CSA;Power circuit 600 V UL;Signalling circuit 690 V IEC 60947-1;Signalling circuit 600 V CSA;Signalling circuit 600 V UL
overvoltage category
III
pollution degree
3
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability
15 Mcycles
electrical durability
0.6 Mcycles 25 A AC-1 <= 440 V;2 Mcycles 9 A AC-3 <= 440 V;2 Mcycles 9 A AC-3e <= 440 V
control circuit type
AC 50/60 Hz standard
coil technology
Without built-in suppressor module
control circuit voltage limits
0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz;0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz;0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz;1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
inrush power in VA
70 VA 60 Hz 0.75 68 °F (20 °C));70 VA 50 Hz 0.75 68 °F (20 °C))
hold-in power consumption in VA
7.5 VA 60 Hz 0.3 68 °F (20 °C));7 VA 50 Hz 0.3 68 °F (20 °C))
heat dissipation
2…3 W 50/60 Hz
operating time
12...22 ms closing;4...19 ms opening
maximum operating rate
3600 cyc/h 140 °F (60 °C)
connections - terminals
Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end;Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end;Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end;Power circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end;Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end;Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end
tightening torque
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm;Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2;Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
auxiliary contact composition
1 NO + 1 NC
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1;Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency
25...400 Hz
minimum switching voltage
17 V signalling circuit
minimum switching current
5 mA signalling circuit
insulation resistance
> 10 MOhm signalling circuit
non-overlap time
1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact
Mounting Support
Plate;Rail
standards
CSA C22.2 No 14;EN 60947-4-1;EN 60947-5-1;IEC 60947-4-1;IEC 60947-5-1;UL 508;IEC 60335-1
Product Certifications
UL;GOST;GL;CCC;BV;LROS (Lloyds register of shipping);CSA;DNV;RINA;UKCA
IP degree of protection
IP20 front face IEC 60529
protective treatment
THIEC 60068-2-30
climatic withstand
IACS E10 exposure to damp heat;IEC 60947-1 Annex Q category D exposure to damp heat
permi
Range of Product
TeSys Deca
Product or Component Type
Contactor
device short name
LC1D
contactor application
Resistive load;Motor control
utilisation category
AC-1;AC-3;AC-4;AC-3e
poles description
3P
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz;Power circuit <= 300 V DC
[Ie] rated operational current
9 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit;25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit;9 A 140 °F (60 °C)) <= 440 V AC AC-3e power circuit
[Uc] control circuit voltage
110 V AC 50/60 Hz
motor power kW
2.2 kW 220...230 V AC 50/60 Hz AC-3);4 kW 380...400 V AC 50/60 Hz AC-3);4 kW 415...440 V AC 50/60 Hz AC-3);5.5 kW 500 V AC 50/60 Hz AC-3);5.5 kW 660...690 V AC 50/60 Hz AC-3);2.2 kW 400 V AC 50/60 Hz AC-4);2.2 kW 220...230 V AC 50/60 Hz AC-3e);4 kW 380...400 V AC 50/60 Hz AC-3e);4 kW 415...440 V AC 50/60 Hz AC-3e);5.5 kW 500 V AC 50/60 Hz AC-3e);5.5 kW 660...690 V AC 50/60 Hz AC-3e)
Maximum Horse Power Rating
1 hp 230/240 V at AC 50/60 Hz for 1 phase;2 hp 200/208 V at AC 50/60 Hz for 3 phase;2 hp 230/240 V at AC 50/60 Hz for 3 phase;5 hp 460/480 V at AC 50/60 Hz for 3 phase;7.5 hp 575/600 V at AC 50/60 Hz for 3 phase;0.33 hp 115 V at AC 50/60 Hz for 1 phase
compatibility code
LC1D
pole contact composition
3 NO
contact compatibility
M2
protective cover
With
[Ith] conventional free air thermal current
25 A 140 °F (60 °C) power circuit;10 A 140 °F (60 °C) signalling circuit
Irms rated making capacity
250 A 440 V power circuit IEC 60947;140 A AC signalling circuit IEC 60947-5-1;250 A DC signalling circuit IEC 60947-5-1
rated breaking capacity
250 A 440 V power circuit IEC 60947
[Icw] rated short-time withstand current
105 A 104 °F (40 °C) - 10 s power circuit;210 A 104 °F (40 °C) - 1 s power circuit;30 A 104 °F (40 °C) - 10 min power circuit;61 A 104 °F (40 °C) - 1 min power circuit;100 A - 1 s signalling circuit;120 A - 500 ms signalling circuit;140 A - 100 ms signalling circuit
associated fuse rating
10 A gG signalling circuit IEC 60947-5-1;25 A gG <= 690 V type 1 power circuit;20 A gG <= 690 V type 2 power circuit
average impedance
2.5 mOhm - Ith 25 A 50 Hz power circuit
power dissipation per pole
1.56 W AC-1;0.2 W AC-3;0.2 W AC-3e
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1;Power circuit 600 V CSA;Power circuit 600 V UL;Signalling circuit 690 V IEC 60947-1;Signalling circuit 600 V CSA;Signalling circuit 600 V UL
overvoltage category
III
pollution degree
3
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
mechanical durability
15 Mcycles
electrical durability
0.6 Mcycles 25 A AC-1 <= 440 V;2 Mcycles 9 A AC-3 <= 440 V;2 Mcycles 9 A AC-3e <= 440 V
control circuit type
AC 50/60 Hz standard
coil technology
Without built-in suppressor module
control circuit voltage limits
0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz;0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz;0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz;1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
inrush power in VA
70 VA 60 Hz 0.75 68 °F (20 °C));70 VA 50 Hz 0.75 68 °F (20 °C))
hold-in power consumption in VA
7.5 VA 60 Hz 0.3 68 °F (20 °C));7 VA 50 Hz 0.3 68 °F (20 °C))
heat dissipation
2…3 W 50/60 Hz
operating time
12...22 ms closing;4...19 ms opening
maximum operating rate
3600 cyc/h 140 °F (60 °C)
connections - terminals
Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end;Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end;Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end;Power circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end;Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end;Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end
tightening torque
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm;Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2;Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
auxiliary contact composition
1 NO + 1 NC
auxiliary contacts type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1;Mirror contact 1 NC IEC 60947-4-1
signalling circuit frequency
25...400 Hz
minimum switching voltage
17 V signalling circuit
minimum switching current
5 mA signalling circuit
insulation resistance
> 10 MOhm signalling circuit
non-overlap time
1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact
Mounting Support
Plate;Rail
standards
CSA C22.2 No 14;EN 60947-4-1;EN 60947-5-1;IEC 60947-4-1;IEC 60947-5-1;UL 508;IEC 60335-1
Product Certifications
UL;GOST;GL;CCC;BV;LROS (Lloyds register of shipping);CSA;DNV;RINA;UKCA
IP degree of protection
IP20 front face IEC 60529
protective treatment
THIEC 60068-2-30
climatic withstand
IACS E10 exposure to damp heat;IEC 60947-1 Annex Q category D exposure to damp heat
permi

Reviews

People Also Searched

LC1D09F7
Schneider Electric (Square D) LC1D09F7
LC1D09F7 price
Schneider Electric (Square D) LC1D09F7 price