ATV212HD37N4 | Altivar 212 VFD, 50 HP/79 amps, 380/480 VAC Three Phase Input/Output, IP20 | Schneider Electric (Square D)
$4,293.44
Get your Special Pricing!
Log In / Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Schneider Electric (Square D)SKU: ATV212HD37N4
List Price
$12,880.00

Web Price:

$4,293.44
Availability: This product is currently available to purchase
Contact us for price breaks on large quantities!
This item ships via FREIGHT
Special Notes
The product is not cancelable or returnable unless found defective
Shipping and Returns Terms

Speak With a Technical Expert

Call (847) 773-1023

Hours: 9am - 5pm CDT M-F

ATV212HD37N4 | Altivar 212 VFD, 50 HP/79 amps, 380/480 VAC Three Phase Input/Output, IP20 | Schneider Electric (Square D)

Schneider Electric (Square D) | ATV212HD37N4
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to ATV212HD37N4

Documents and manuals

Schneider Electric (Square D) ATV212HD37N4 Documents

Overview

Details for ATV212HD37N4

ATV212HD37N4: Schneider Electric's Variable Speed Drive Schneider Electric's ATV212HD37N4 is a variable speed drive (VSD) designed to control the speed and torque of AC motors. Featuring a compact and robust design, this VSD offers precise motor control for a variety of industrial applications. The ATV212HD37N4 is rated for 50 HP at 480V, making it suitable for heavy-duty applications requiring high power and torque. It utilizes advanced vector control algorithms to provide optimal motor performance, with precise speed regulation and smooth acceleration/deceleration. This translates to increased efficiency, reduced energy consumption, and extended motor life. Key features of the ATV212HD37N4 include: * Modbus and CANopen communication protocols for seamless integration into control systems * Enhanced safety features such as Safe Torque Off (STO) and Safe Stop 1 (SS1) * Built-in PLC functionality for customizable control * Compact design for easy installation in tight spaces The ATV212HD37N4 is a versatile and reliable VSD that meets the demands of industrial engineers and maintenance professionals. Our HVAC supply store offers this product at competitive prices with fast shipping. Contact us today to learn more and order your ATV212HD37N4 for optimal motor control and performance. This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 37kW / 50hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 38.1kg and its dimensions are, 240mm wide, 550mm high, 244mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet. It is eco-friendly and complies with directives such as RoHS, WEEE, etc.relating to environmental protection.
device short name
ATV212
product destination
Asynchronous motors
Phase
3 phase
motor power kW
37 kW
Maximum Horse Power Rating
50 hp
supply voltage limits
323…528 V
supply frequency
50...60 Hz - 5...5 %
line current
68.9 A 380 V;54.4 A 480 V
Range of Product
Altivar 212
Product or Component Type
Variable speed drive
Product Specific Application
Pumps and fans in HVAC
communication port protocol
METASYS N2;BACnet;Modbus;APOGEE FLN;LonWorks
[Us] rated supply voltage
380...480 V - 15...10 %
EMC filter
Class C2 EMC filter integrated
IP degree of protection
IP21
apparent power
52 kVA 380 V
continuous output current
79 A 380 V;79 A 460 V
maximum transient current
86.9 A 60 s
speed drive output frequency
0.5…200 Hz
speed range
1…10
speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
local signalling
for DC bus energized 1 LED (red)
output voltage
<= power supply voltage
isolation
Electrical between power and control
type of cable
Without mounting kit 1 IEC cable 113 °F (45 °C);copper 90 °C / XLPE/EPR;Without mounting kit 1 IEC cable 113 °F (45 °C);copper 70 °C / PVC;With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C);copper 75 °C / PVC
electrical connection
VIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES terminal 0.00 in² (2.5 mm²) / AWG 14;L1/R;L2/S;L3/T terminal 0.08 in² (50 mm²) / AWG 1/0
tightening torque
5.31 lbf.in (0.6 N.m) VIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES);212.42 lbf.in (24 N.m);212 lb.in L1/R;L2/S;L3/T)
supply
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %;<10 A overload and short-circuit protection;Internal supply 24 V DC 21…27 V);<200 A overload and short-circuit protection
sampling duration
2 ms +/- 0.5 ms F discrete;2 ms +/- 0.5 ms R discrete;2 ms +/- 0.5 ms RES discrete;3.5 ms +/- 0.5 ms VIA analog;22 ms +/- 0.5 ms VIB analog
response time
FM 2 ms +/- 0.5 ms analog;FLA;FLC 7 ms +/- 0.5 ms discrete;FLB;FLC 7 ms +/- 0.5 ms discrete;RY;RC 7 ms +/- 0.5 ms discrete
accuracy
+/- 0.6 % VIA) for a temperature variation 60 °C;+/- 0.6 % VIB) for a temperature variation 60 °C;+/- 1 % FM) for a temperature variation 60 °C
linearity error
VIA +/- 0.15 % of maximum value input;VIB +/- 0.15 % of maximum value input;FM +/- 0.2 % output
analogue output type
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits;FM switch-configurable current 0...20 mA 970 Ohm 10 bits
discrete output type
Configurable relay logic FLA;FLC) NO - 100000 cycles;Configurable relay logic FLB;FLC) NC - 100000 cycles;Configurable relay logic RY;RC) NO - 100000 cycles
minimum switching current
3 mA 24 V DC configurable relay logic
maximum switching current
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL;R);5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL;R);2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL;R);2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL;R)
discrete input type
F programmable 24 V DC level 1 PLC 4700 Ohm;R programmable 24 V DC level 1 PLC 4700 Ohm;RES programmable 24 V DC level 1 PLC 4700 Ohm
discrete input logic
Positive logic (source) F;R;RES);<= 5 V;>= 11 V;Negative logic (sink) F;R;RES);>= 16 V;<= 10 V
dielectric strength
3535 V DC between earth and power terminals;5092 V DC between control and power terminals
insulation resistance
>= 1 mOhm 500 V DC for 1 minute
frequency resolution
Display unit 0.1 Hz;Analog input 0.024/50 Hz
Communication Service
Read holding registers (03) 2 words maximum;Monitoring inhibitable;Write single register (06);Write multiple registers (16) 2 words maximum;Time out setting from 0.1 to 100 s;Read device identification (43)
option card
Communication card LonWorks
power dissipation in W
976 W
air flow
88235.05 Gal/hr(US) (334 m3/h)
functionality
Mid
specific application
HVAC
Variable speed drive application selection
Building - HVAC Compressor for scroll;Building - HVAC Fan;Building - HVAC Pump
Motor power range AC-3
30…50 kW 380…440 V 3 phase;30…50 kW 480…500 V 3 phase
motor starter type
Variable speed drive
discrete output number
2
analogue input number
2
analogue input type
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable PTC probe 0...6 probes 1500 Ohm;VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
analogue output number
1
physical interface
2-wire RS 485
Connector Type
1 open style;1 RJ45
Transmission Rate
9600 bps or 19200 bps
transmission frame
RTU
number of addresses
1…247
data format
8 bits;1 stop;odd even or no configurable parity
type of polarization
No impedance
asynchronous motor control profile
Flux vector control without sensor;standard;Voltage/frequency ratio;5 points;Voltage/frequency ratio;2 points;Voltage/frequency ratio - Energy Saving;quadratic U/f;Voltage/frequency ratio;automatic IR compensation (U/f + automatic Uo)
torque accuracy
+/- 15 %
transient overtorque
120 % of nominal motor torque +/- 10 % 60 s
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 3200 s;Automatic based on the load
motor slip compensation
Not available in voltage/frequency ratio motor control;Automatic whatever the load;Adjustable
switching frequency
6...16 kHz adjustable;8...16 kHz with derating factor
nominal switching frequency
8 kHz
braking to standstill
By DC injection
Network Frequency
47.5...63 Hz
prospective line Isc
22 kA
protection type
Overheating protection drive;Thermal power stage drive;Short-circuit between motor phases drive;Input phase breaks drive;Overcurrent betwe

Specifications

Item Number
ATV212HD37N4
Brand
Schneider Electric (Square D)
Brand
Square D
device short name
ATV212
product destination
Asynchronous motors
Phase
3 phase
motor power kW
37 kW
Maximum Horse Power Rating
50 hp
supply voltage limits
323…528 V
supply frequency
50...60 Hz - 5...5 %
line current
68.9 A 380 V;54.4 A 480 V
Range of Product
Altivar 212
Product or Component Type
Variable speed drive
Product Specific Application
Pumps and fans in HVAC
communication port protocol
METASYS N2;BACnet;Modbus;APOGEE FLN;LonWorks
[Us] rated supply voltage
380...480 V - 15...10 %
EMC filter
Class C2 EMC filter integrated
IP degree of protection
IP21
apparent power
52 kVA 380 V
continuous output current
79 A 380 V;79 A 460 V
maximum transient current
86.9 A 60 s
speed drive output frequency
0.5…200 Hz
speed range
1…10
speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
local signalling
for DC bus energized 1 LED (red)
output voltage
<= power supply voltage
isolation
Electrical between power and control
type of cable
Without mounting kit 1 IEC cable 113 °F (45 °C);copper 90 °C / XLPE/EPR;Without mounting kit 1 IEC cable 113 °F (45 °C);copper 70 °C / PVC;With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C);copper 75 °C / PVC
electrical connection
VIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES terminal 0.00 in² (2.5 mm²) / AWG 14;L1/R;L2/S;L3/T terminal 0.08 in² (50 mm²) / AWG 1/0
tightening torque
5.31 lbf.in (0.6 N.m) VIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES);212.42 lbf.in (24 N.m);212 lb.in L1/R;L2/S;L3/T)
supply
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %;<10 A overload and short-circuit protection;Internal supply 24 V DC 21…27 V);<200 A overload and short-circuit protection
sampling duration
2 ms +/- 0.5 ms F discrete;2 ms +/- 0.5 ms R discrete;2 ms +/- 0.5 ms RES discrete;3.5 ms +/- 0.5 ms VIA analog;22 ms +/- 0.5 ms VIB analog
response time
FM 2 ms +/- 0.5 ms analog;FLA;FLC 7 ms +/- 0.5 ms discrete;FLB;FLC 7 ms +/- 0.5 ms discrete;RY;RC 7 ms +/- 0.5 ms discrete
accuracy
+/- 0.6 % VIA) for a temperature variation 60 °C;+/- 0.6 % VIB) for a temperature variation 60 °C;+/- 1 % FM) for a temperature variation 60 °C
linearity error
VIA +/- 0.15 % of maximum value input;VIB +/- 0.15 % of maximum value input;FM +/- 0.2 % output
analogue output type
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits;FM switch-configurable current 0...20 mA 970 Ohm 10 bits
discrete output type
Configurable relay logic FLA;FLC) NO - 100000 cycles;Configurable relay logic FLB;FLC) NC - 100000 cycles;Configurable relay logic RY;RC) NO - 100000 cycles
minimum switching current
3 mA 24 V DC configurable relay logic
maximum switching current
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL;R);5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL;R);2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL;R);2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL;R)
discrete input type
F programmable 24 V DC level 1 PLC 4700 Ohm;R programmable 24 V DC level 1 PLC 4700 Ohm;RES programmable 24 V DC level 1 PLC 4700 Ohm
discrete input logic
Positive logic (source) F;R;RES);<= 5 V;>= 11 V;Negative logic (sink) F;R;RES);>= 16 V;<= 10 V
dielectric strength
3535 V DC between earth and power terminals;5092 V DC between control and power terminals
insulation resistance
>= 1 mOhm 500 V DC for 1 minute
frequency resolution
Display unit 0.1 Hz;Analog input 0.024/50 Hz
Communication Service
Read holding registers (03) 2 words maximum;Monitoring inhibitable;Write single register (06);Write multiple registers (16) 2 words maximum;Time out setting from 0.1 to 100 s;Read device identification (43)
option card
Communication card LonWorks
power dissipation in W
976 W
air flow
88235.05 Gal/hr(US) (334 m3/h)
functionality
Mid
specific application
HVAC
Variable speed drive application selection
Building - HVAC Compressor for scroll;Building - HVAC Fan;Building - HVAC Pump
Motor power range AC-3
30…50 kW 380…440 V 3 phase;30…50 kW 480…500 V 3 phase
motor starter type
Variable speed drive
discrete output number
2
analogue input number
2
analogue input type
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable PTC probe 0...6 probes 1500 Ohm;VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
analogue output number
1
physical interface
2-wire RS 485
Connector Type
1 open style;1 RJ45
Transmission Rate
9600 bps or 19200 bps
transmission frame
RTU
number of addresses
1…247
data format
8 bits;1 stop;odd even or no configurable parity
type of polarization
No impedance
asynchronous motor control profile
Flux vector control without sensor;standard;Voltage/frequency ratio;5 points;Voltage/frequency ratio;2 points;Voltage/frequency ratio - Energy Saving;quadratic U/f;Voltage/frequency ratio;automatic IR compensation (U/f + automatic Uo)
torque accuracy
+/- 15 %
transient overtorque
120 % of nominal motor torque +/- 10 % 60 s
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 3200 s;Automatic based on the load
motor slip compensation
Not available in voltage/frequency ratio motor control;Automatic whatever the load;Adjustable
switching frequency
6...16 kHz adjustable;8...16 kHz with derating factor
nominal switching frequency
8 kHz
braking to standstill
By DC injection
Network Frequency
47.5...63 Hz
prospective line Isc
22 kA
protection type
Overheating protection drive;Thermal power stage drive;Short-circuit between motor phases drive;Input phase breaks drive;Overcurrent betwe
device short name
ATV212
product destination
Asynchronous motors
Phase
3 phase
motor power kW
37 kW
Maximum Horse Power Rating
50 hp
supply voltage limits
323…528 V
supply frequency
50...60 Hz - 5...5 %
line current
68.9 A 380 V;54.4 A 480 V
Range of Product
Altivar 212
Product or Component Type
Variable speed drive
Product Specific Application
Pumps and fans in HVAC
communication port protocol
METASYS N2;BACnet;Modbus;APOGEE FLN;LonWorks
[Us] rated supply voltage
380...480 V - 15...10 %
EMC filter
Class C2 EMC filter integrated
IP degree of protection
IP21
apparent power
52 kVA 380 V
continuous output current
79 A 380 V;79 A 460 V
maximum transient current
86.9 A 60 s
speed drive output frequency
0.5…200 Hz
speed range
1…10
speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
local signalling
for DC bus energized 1 LED (red)
output voltage
<= power supply voltage
isolation
Electrical between power and control
type of cable
Without mounting kit 1 IEC cable 113 °F (45 °C);copper 90 °C / XLPE/EPR;Without mounting kit 1 IEC cable 113 °F (45 °C);copper 70 °C / PVC;With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C);copper 75 °C / PVC
electrical connection
VIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES terminal 0.00 in² (2.5 mm²) / AWG 14;L1/R;L2/S;L3/T terminal 0.08 in² (50 mm²) / AWG 1/0
tightening torque
5.31 lbf.in (0.6 N.m) VIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES);212.42 lbf.in (24 N.m);212 lb.in L1/R;L2/S;L3/T)
supply
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %;<10 A overload and short-circuit protection;Internal supply 24 V DC 21…27 V);<200 A overload and short-circuit protection
sampling duration
2 ms +/- 0.5 ms F discrete;2 ms +/- 0.5 ms R discrete;2 ms +/- 0.5 ms RES discrete;3.5 ms +/- 0.5 ms VIA analog;22 ms +/- 0.5 ms VIB analog
response time
FM 2 ms +/- 0.5 ms analog;FLA;FLC 7 ms +/- 0.5 ms discrete;FLB;FLC 7 ms +/- 0.5 ms discrete;RY;RC 7 ms +/- 0.5 ms discrete
accuracy
+/- 0.6 % VIA) for a temperature variation 60 °C;+/- 0.6 % VIB) for a temperature variation 60 °C;+/- 1 % FM) for a temperature variation 60 °C
linearity error
VIA +/- 0.15 % of maximum value input;VIB +/- 0.15 % of maximum value input;FM +/- 0.2 % output
analogue output type
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits;FM switch-configurable current 0...20 mA 970 Ohm 10 bits
discrete output type
Configurable relay logic FLA;FLC) NO - 100000 cycles;Configurable relay logic FLB;FLC) NC - 100000 cycles;Configurable relay logic RY;RC) NO - 100000 cycles
minimum switching current
3 mA 24 V DC configurable relay logic
maximum switching current
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL;R);5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL;R);2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL;R);2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL;R)
discrete input type
F programmable 24 V DC level 1 PLC 4700 Ohm;R programmable 24 V DC level 1 PLC 4700 Ohm;RES programmable 24 V DC level 1 PLC 4700 Ohm
discrete input logic
Positive logic (source) F;R;RES);<= 5 V;>= 11 V;Negative logic (sink) F;R;RES);>= 16 V;<= 10 V
dielectric strength
3535 V DC between earth and power terminals;5092 V DC between control and power terminals
insulation resistance
>= 1 mOhm 500 V DC for 1 minute
frequency resolution
Display unit 0.1 Hz;Analog input 0.024/50 Hz
Communication Service
Read holding registers (03) 2 words maximum;Monitoring inhibitable;Write single register (06);Write multiple registers (16) 2 words maximum;Time out setting from 0.1 to 100 s;Read device identification (43)
option card
Communication card LonWorks
power dissipation in W
976 W
air flow
88235.05 Gal/hr(US) (334 m3/h)
functionality
Mid
specific application
HVAC
Variable speed drive application selection
Building - HVAC Compressor for scroll;Building - HVAC Fan;Building - HVAC Pump
Motor power range AC-3
30…50 kW 380…440 V 3 phase;30…50 kW 480…500 V 3 phase
motor starter type
Variable speed drive
discrete output number
2
analogue input number
2
analogue input type
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable PTC probe 0...6 probes 1500 Ohm;VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
analogue output number
1
physical interface
2-wire RS 485
Connector Type
1 open style;1 RJ45
Transmission Rate
9600 bps or 19200 bps
transmission frame
RTU
number of addresses
1…247
data format
8 bits;1 stop;odd even or no configurable parity
type of polarization
No impedance
asynchronous motor control profile
Flux vector control without sensor;standard;Voltage/frequency ratio;5 points;Voltage/frequency ratio;2 points;Voltage/frequency ratio - Energy Saving;quadratic U/f;Voltage/frequency ratio;automatic IR compensation (U/f + automatic Uo)
torque accuracy
+/- 15 %
transient overtorque
120 % of nominal motor torque +/- 10 % 60 s
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 3200 s;Automatic based on the load
motor slip compensation
Not available in voltage/frequency ratio motor control;Automatic whatever the load;Adjustable
switching frequency
6...16 kHz adjustable;8...16 kHz with derating factor
nominal switching frequency
8 kHz
braking to standstill
By DC injection
Network Frequency
47.5...63 Hz
prospective line Isc
22 kA
protection type
Overheating protection drive;Thermal power stage drive;Short-circuit between motor phases drive;Input phase breaks drive;Overcurrent betwe

Reviews

People Also Searched

ATV212HD37N4
Schneider Electric (Square D) ATV212HD37N4
ATV212HD37N4 price
Schneider Electric (Square D) ATV212HD37N4 price