WWDP-2-LCD | Differential pressure transmitter | selectable 10 | 20 | 50 | 100 psid | 100 psi max. working pressure | with LCD. | Dwyer Instruments
$1,359.82
Get your Special Pricing!
Log In / Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Dwyer InstrumentsSKU: WWDP-2-LCD
Availability: Get a Quote

Speak With a Technical Expert

Call (847) 773-1023

Hours: 9am - 5pm CDT M-F

WWDP-2-LCD | Differential pressure transmitter | selectable 10 | 20 | 50 | 100 psid | 100 psi max. working pressure | with LCD. | Dwyer Instruments

Dwyer Instruments | WWDP-2-LCD
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to WWDP-2-LCD

Documents and manuals

Dwyer Instruments WWDP-2-LCD Documents

Overview

Details for WWDP-2-LCD

Dwyer Instruments WWDP-2-LCD: Precision Pressure Measurement with LCD Display The Dwyer Instruments WWDP-2-LCD is an advanced digital pressure transmitter designed for industrial applications. It features a large LCD display that provides clear and precise readings of pressure levels within a range of 0-10, 0-20, 0-50, or 0-100 inches of water column (#). Versatile and Durable: Its compact design and rugged construction make it suitable for various industrial environments. Housed in a durable NEMA 4 enclosure, the WWDP-2-LCD withstands harsh conditions and provides long-lasting performance. Accuracy and Reliability: Equipped with a solid-state pressure sensor, it offers exceptional accuracy and reliability. The digital display eliminates parallax errors, ensuring precise readings every time. Applications: Ideal for monitoring pressure in HVAC systems, clean rooms, and industrial processes, the WWDP-2-LCD is a valuable tool for industrial engineers and maintenance professionals. Features: * Pressure range: 0-10/20/50/100# * LCD display for clear readings * Solid-state pressure sensor for accuracy * NEMA 4 enclosure for durability * Versatile for various industrial applications

Series WWDP Differential Pressure Transmitter

Selectable Ranges of Uni-Directional or Bi-Directional, Selectable Outputs

The Series WWDP Wet-to-Wet Differential Pressure Transmitter offers everything in one package by having 30 field selectable variations in just 3 models. The WWDP provides field selectable unidirectional and bidirectional pressure ranges, configurable 0-5, 1-5, 0-10 VDC, and 4 to 20 mA output. It also provides an auto-zero capability. The field selectable port swap feature eliminates costly replumbing if the unit is improperly installed or if the transmitter is simply replaced. An optional LCD display is available for on-sight indication of line and differential pressure. The all cast aluminum housing is rated NEMA 4 (IP66). These features make the WWDP transmitter an ideal instrument for measuring the flow of various liquids and gases, pressure drop across filters, measurement of liquid level or pressurized vessels, and for use in energy management and process control systems.

Calibration Option available under Accessories.

Product Applications

  • Monitor differential pressure of a chiller
  • Filter monitoring
  • Liquid level
  • Pressure vessels
  • Process control
  • Energy management
  • Versatile device for liquid or gas supports designs requiring more precise measurements in support of application
  • Field selectable port swap eliminates costly re-plumbing if unit is re-installed or replaced
  • Uni-directional and bi-directional pressure selection with configurable output provides a single device that can meet broad application needs without having to specify multiple devices
  • Optional LCD display provides local status to identify operational conditions
  • NEMA 4 rated enclosure provides protection in harsh environments permitting outdoor monitoring or in areas where dust and particulate matter exists

Specifications

Series
WWDP Differential Pressure Transmitter
freeship
Category/Type
Pressure
Type
Differential Pressure
Series
WWDP Differential Pressure Transmitter
Service
Gases or liquids compatible with 17-4 PH stainless steel.
Accuracy
All pressure ranges have ±1% full scale accuracy except the lowest selectable range of each unit is ±2% full scale.
Stability
±0.5% per year.
Temperature Limits
Compensated temperature range: 32 to 130°F (0 to 54°C); Operating temperature range: -4 to 185°F (-20 to 85°C).
Pressure Limits
Max working pressure: WWDP-1: 50 psi; WWDP-2: 100 psi; WWDP-3: 250 psi; Proof pressure: 2.2X of full scale; Burst pressure: 40X of full scale.
Thermal Effect
2% FS/100°F (50°C) includes zero and span.
Power Requirements
12 to 30 VDC/18 to 28 VAC (Reverse Excitation Protected). NOTE: 4 to 20 mA output cannot be powered with AC voltage.
Output Signal
Selectable 0 to 5; 0 to 10 and 1 tp 5 VDC; 4 to 20 mA.
Zero & Span
Digital "re" zero button (should be used when changing ranges). Span can be adjusted by changing between field selectable ranges.
Response Time
1 to 5 sec (selectable).
Loop Resistance
1000 Ω.
Current Consumption
VDC power: 0 to 5; 1 to 5 VDC output 4 mA (typ); 0 to 10 VDC output 5 mA (typ); 4 to 20 mA output 20 mA max. Current consumption will equal the transmitter output in current mode. VAC power: 0 to 5; 1 to 5; 0 to 10 VDC output 40 mA (typ).
Electrical Connections
1/2" conduit.
Process Connections
1/8" female NPT internal.
Enclosure Rating
Designed to meet NEMA 4 (IP66).
Mounting Orientation
Vertical; mount the pressure ports down (keeps debris from building up inside the pressure port).
Weight
1.5 lb (680.4 g).
Agency Approvals
CE.