TE-6362M-1 | TEMPERATURE SENSOR; WELL INSERTION TEMP SENSOR 10K THERMISTOR SENSOR 8" PROBE | Johnson Controls
Overview
Details for TE-6362M-1
Description
The TE-6300 Temperature Sensor line provides economical solutions for a wide variety of temperature sensing needs, including wall-mount, outdoor-air, duct, strap-mount, well-insertion, duct-averaging, and VAV Modular Assembly (VMA) flangemount duct-probe applications. The TE-6300 line offers both a metal and a plastic enclosure for the most popular models. Sensors are available in the following types:
- 1k ohm thin-film nickel
- 1k ohm nickel averaging
- 1k ohm thin-film platinum
- 100 ohm platinum equivalent averaging
- 1k ohm platinum equivalent averaging
- 2.2k (2,252) ohm thermistor
- 10k ohm thermistor, Johnson Controls® Type II
Refer to the TE-6300 Series Temperature Sensors Product Bulletin (LIT-216320) for important product application information.
Features and Benefits
Each sensor is packaged with the necessary mounting accessories to maximize ordering and installation ease and to reduce both commissioning time and cost.
- Full Line of Versatile Sensors—Supports all your temperature sensing needs from a single supplier: wall-mount, outdoor-air, duct, duct-averaging, strap-mount, wellinsertion, and flange-mount duct-probe.
- Single Assembly Ordering—Simplifies ordering; provides a complete assembly in one box.
- Models Featuring an Integral National Pipe Thread (NPT) Adaptor—Increase sensor connection strength, which eliminates the need for a special adaptor.
- Models with a Stainless Steel Sensor Probe—Protect the sensor while increasing corrosion resistance.
- Metal Enclosure (TE-63xxE, TE-63xxM, and TE-63xxV Models)—Meets plenum requirements.
- Models Featuring a Retainer for the Sensor Holder—Allow you to lock the sensor holder into the conduit box.
- Brushed Stainless Steel Mounting Plate—Offers a durable, aesthetically pleasing design.
- Low Profile Flush Mount Design (TE-63xxF Models)—Provides a tamperproof installation ideally suited for schools, sporting complexes, retailers, prisons, and more
All TE-6300 Series Temperature Sensors are two-wire, passive, resistance-output devices.
TE-63xxA Models
The TE-63xxA (adjustable length) models:
- provide a thermoplastic mounting flange and gland nut to adjust the length of the probe
- include two hex-head self-drilling screws for mounting
- come equipped with a 10 ft (3 m) plenum-rated cable with 1/4 in. (6.35 mm) internal thread insulated quick-connect terminations on leads TE-
63xxE Models
The TE-63xxE (economizer mount) models:
- provide a stainless steel mounting flange
- include two hex-head self-drilling screws for mounting
- meet UL 1995 plenum use requirements
TE-63xxF
Models The TE-63xxF (flush mount) models:
- provide a low profile when installed in an electrical box
- thermally isolate sensor from the wall with a foam pad
- offer a rugged stainless steel cover
- provide 22 AWG (0.6 mm diameter) lead wires with low voltage installation
63xxM Models
The TE-63xxM (metal enclosure) models:
- come with a corrosion-protected steel enclosure with a 0.88 in. (22 mm) hole for a 1/2 in. (12.7 mm) conduit fitting
- include two hex-head self-drilling screws for mounting the duct and duct-averaging models
- offer either a direct-mount or 1/2-14 NPT threaded well sensor holder for mounting in TE-6300W Series Thermowells (well models; order the thermowell separately)
- provide optional well sensor holders (order separately) to mount duct models in thermowells
- meet UL 1995 plenum use requirements
- offer optional accessory kit (order separately) to replace plastic hole plug and wiring bushing to meet International Mechanical Code (IMC) requirements
TE-63xxP
Models The TE-63xxP (plastic enclosure) models:
- provide a thermoplastic conduit box with 1/2-14 internal NPT for connecting to conduit
- provide aluminum mounting plate and 1/2-14 internal NPT hub mounting options for the duct and duct-averaging models
- use the 1/2-14 internal NPT to mount the outdoor air models directly to rigid conduit
- include sensor holders to mount duct models in thermowells (order thermowell separately)
- offer an optional accessory metal cover and gasket kit (order separately) to replace the plastic cover to meet UL 1995 plenumuse requirements
- include a replaceable sensing probe on duct-probe, outdoor-air, and well-insertion models
TE-63x4P
Wall Mount Models The TE-63x4P (plastic enclosure) models:
- come with a white thermoplastic ventilated cover with a brushed aluminum face plate and a steel mounting plate for surface mounting
- include faceplates for both horizontal and vertical mounting
- offer an accessory mounting kit for mounting to a standard electrical box
- offer optional covers
TE-63xS Models
The TE-63xS (strap-mount) models:
- provide a 1/4 in. (6.35 mm) diameter stainless steel probe without an enclosure
- include three cable ties for mounting to pipe up to 2-5/8 in. (67 mm) in diameter
- come equipped with a 10 ft (3 m) plenum-rated cable • meet UL 1995 plenum use requirements
- offer an accessory mounting kit for mounting to a pipe up to 11 in. (280 mm) in diameter
TE-63xxV Models
The TE-63xxV (VAV flange mount) models:
- provide a stainless steel mounting flange with two hex-head self-drilling mounting screws
- come equipped with a 10 ft (3 m) plenum-rated cable with 1/4 in. (6.35 mm) internal thread insulated quick-connect terminations on leads
- meet UL 1995 plenum use requirements
Repair Information
If the TE-6300 Series Temperature Sensor fails to operate within its specifications, replace the unit. For information on replacement temperature sensors and replacement sensor probes, refer to the TE-6300 Series Temperature Sensors Product Bulletin (LIT-216320).
Specifications
Item Number | TE-6362M-1 |
Brand | Johnson Controls |