Overview

Details for TABKIT-NIST

NIST Calibrated TestAdjBalKit: The TABKIT-NISTfrom Dwyer Instruments is a high-precision testing and adjustment kit designed for HVAC/R professionals. It includes a NIST-traceable digital manometer, a digital temperature probe, and a set of precision adjustment tools. The kit is used to calibrate and adjust pressure switches, transmitters, and other HVAC/R components. The digital manometer features a large, backlit display, a built-in pressure sensor, and a variety of pressure units. The digital temperature probe is used to measure temperature in Fahrenheit or Celsius. The kit also includes a set of precision adjustment tools, including a screwdriver, a hex key, and a set of Allen wrenches. Our HVAC supply store offers the best prices and fast shipping on all Dwyer Instruments products!

SERIES TABKIT TEST, ADJUST, AND BALANCE KIT

A Complete Balancing Technician Solution

The Series TABKIT Test, Adjust, and Balance Kit combines all essential air, water,temperature, humidity, and electrical test instruments are included in this kit, creatingthe ultimate air and water balancing solution. The Series TABKIT has everything abalancing technician needs in a single case. A certificate of NIST calibration is includedfor each instrument inside the kit, ensuring accurate, durable, repeatable, and reliablemeasurements every time. When the products need to be recalibrated, save time bysending everything back to Dwyer. Our lab is able to service all equipment within thekit, and ensure they’re as accurate as the day you originally received them.


Complete Kit Includes:

  • Model 160G Averaging Air Flow Grid
  • Model DP3 Bluetooth-Enabled Wireless Differential Pressure Module
  • Model AP3 Bluetooth-Enabled Wireless Thermo-Anemometer Probe
  • Model RP3 Bluetooth-Enabled Wireless Thermo-Hygrometer Probe
  • Model VP3 Bluetooth-Enabled Wireless 100 mm Vane Thermo-Anemometer Probe
  • Model TAC-L Portable Digital Tachometer
  • Model CM-1 Digital Clamp Meter
  • Series 490W Wireless Hydronic Differential Pressure Manometer
  • Model 160F 18" Straight Stainless Steel Pitot Tube
  • Model 160-18 18" Stainless Steel Pitot Tube
  • Two Model A-303 Static Pressure Tips with Magnetic Mounting
  • Cooper-Atkins Model TM99A Thermistor Temperature Instrument
  • Cooper-Atkins Model 1075 General Purpose Puncture Probe
  • Hard Case


California Residents:  Click Here for Proposition 65 WARNING.

Product Applications

  • Building balancing
  • Building commissioning
  • Testing HVAC equipment performance
  • Everything a balancing technician needs in a single case
  • Best in class low flow velocity readings
  • Repeatable measurements

Specifications

Series
TABKIT TEST; ADJUST; AND BALANCE KIT
freeship
Category/Type
Test Equipment
Type
HVAC Balancing Instruments
Series
TABKIT TEST; ADJUST; AND BALANCE KIT
AIR
Series DP3
Accuracy*
±0.5% FS span @ 25°C(includes non linearity; hysteresis; and nonrepeatability).
Pressure Limits
±10 in w.c. (±2.5 kPa).
Temperature Limits
Operating: -4 to140°F (-20 to 60°C); Storage: -40 to 185°F(-40 to 85°C).
Model AP3
Range
Air velocity: 0 to 6000 FPM (0 to 30 m/s); Volumetric air: 999;999 in selected flow units; Temperature: -20 to212°F (-29 to 100°C).
Accuracy
Air velocity*: ±3% FS withintemperature range of 40 to 90°F (4 to32°C) -TAB option: 50 to 3900 FPM (0.25to 20 m/s); Temperature: ±0.5°F (±0.28°C).
Model VP3
Range
Air velocity: 40 to 5000 FPM (0.2to 25 m/s); Volumetric air: 999;999 inselected flow units; Temperature: -20 to212°F (-29 to 100°C); Relative humidity: 0to 100% RH.
Accuracy
Air velocity*: 0.25 to 10m/s: ±1.5% of reading ±20 FPM (±0.1m/s); 10 to 20 m/s: 1.5% of reading±40 FPM (±0.2 m/s); 20 to 25 m/s:±1.5% of reading ±60 FPM (±0.3 m/s);Temperature: ±0.54°F @ 77°F (±0.3°C@ 25°C); Relative humidity: ±2% @ 77°F(25°C) (10 to 90% RH); ±4% (0 to 10% RHand 90 to 100%).
Resolution
1 FPM (0.001 m/s).
TEMPERATURE
TM99A and 1075
Range
0 to 200°F (-20 to 100°C).
Accuracy*
±0.5% of reading + 2.0°F (±0.5% of reading + 1.0°C).
Resolution
0.1°F (0.1°C).
HUMIDITY
Model RP3
Range
RH: 0 to 100% (noncondensing);Temperature: -22 to 140°F(-30 to 60°C).
Accuracy
RH*: ±2% @ 25°C (10 to90% RH); ±4% (0 to 10; 90 to 100% RH);Temperature: ±0.54°F @ 77°F (±0.3°C).
ELECTRICAL
Model CM-1
AC Voltage
0.1-600 V ± (1.0% + 5 dgt).
DC Voltage
0.1-600 V ± (1.0% + 3 dgt).
AC Current
0.1-400 A ± (2.0% + 10 dgt).
Resistance
0.1-400 Ω ± (1.0% + 5 dgt).
ROTATION
Model TAC-L
Range
Non-contact (RPM): 2.5 to99;999 RPM; Contact (RPM): 0.5 to19;999 RPM; Surface speed (m/min):0.05 to 19;999 m/min.
Resolution
Non-contact* (RPM): 0.1RPM (2.5 to 999.9 RPM); 1 RPM (1000to 19;000 RPM); Surface speed (m/min):0.01 m/min (0.05 to 99.99 m/min); 0.1 m/min (100.0 to 1999.9 m/min).
HYDRONIC
A-490W-6
Range
0.4 to 200 psi; 3 to 1400 kPa. 0.4 to 75 psi; 3 to 500 kPa.
Accuracy
2% of reading ±1 psi; 2% of reading ±7 kPa. 2% of reading ±0.5 psi; 2% of reading ±3.5 kPa.
Resolution
0.1 psi; 1.0 kPa. 0.01 psi; 0.1 kPa.
*NIST calibrated.

Reviews

People Also Searched

TABKIT-NIST
Dwyer Instruments TABKIT-NIST
TABKIT NIST
TABKITNIST
Dwyer Instruments TABKIT NIST
Dwyer Instruments TABKITNIST
TABKIT-NIST price
Dwyer Instruments TABKIT-NIST price
TABKIT NIST price
TABKITNIST price
Dwyer Instruments TABKIT NIST price
Dwyer Instruments TABKITNIST price