LTA1203S-2 | Electronic, (120V) Auto Reset Low Water Cut-Off (Water) | Taco
$151.73
Get your Special Pricing!
Log In / Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: TacoSKU: LTA1203S-2
List Price
$294.88
$151.73
Availability: IN STOCK
Contact us for price breaks on large quantities!
Orders over $999 ship FREE*
The product is not cancelable or returnable unless found defective
*Free shipping applies within the continental US and weighing less than 50 lbs.
Shipping and Returns Terms

Speak With a Technical Expert

Call (847) 773-1023

Hours: 9am - 5pm CDT M-F

LTA1203S-2 | Electronic, (120V) Auto Reset Low Water Cut-Off (Water) | Taco

Taco | LTA1203S-2
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to LTA1203S-2

Documents and manuals

Taco LTA1203S-2 Documents

Overview

Details for LTA1203S-2

Taco 120V A/R Low Water Cut Off: LTA1203S-2Protect your boiler system with the Taco LTA1203S-2 120V Automatic Reset Low Water Cut Off (LWCO). This critical safety device is designed to shut off your burner in the event of low water levels, preventing costly damage to your boiler and ensuring the safety of your facility. Featuring a durable 3/4" immersion probe and a robust construction, the LTA1203S-2 provides reliable operation even in challenging industrial environments. Its A/R (automatic reset) functionality allows for automatic reset once water levels have been restored, eliminating the need for manual intervention. With its compact size and easy installation, the Taco LTA1203S-2 is a convenient and effective solution for protecting your boiler system. It is ideal for use in commercial and industrial applications, including boilers, hot water heaters, and hydronic heating systems. Upgrade your boiler safety today with the Taco LTA1203S-2 120V A/R Low Water Cut Off. Our HVAC supply store [Insert CTA Here]!
Accurate, Dependable Protection for All Boiler Types
The Taco Low Water Cutoff provides accurate and dependable protection for all types of boilers, from small residential hot water boilers to large industrial steam units. This probe-style Low Water Cutoff features patented DualVision Technology, external LED’s and simplified wiring for easy installation and testing and automatic, manual reset mode and are available in 24VAC or 120VAC models. The Taco Low Water Cutoff can act as either the primary or secondary low water cutoff on low-pressure steam boilers, the primary limit control on hot water boilers or to protect pumps from running dry in condensate receiver tank applications. The Low Water Cutoff can also activate alarm systems or automatic water feeders.
Performance Data
LF Model
Max. Pressures Steam: 250 psi (17.6 kg/cm2)
Max. Pressures Hot Water: 250 psi (17.6 kg/cm2) @250˚F (121˚C)
Max. Ambient Temp.: 150˚F (66˚C)
Delays: Automatic
Probe Sensitivity: 20K Ohms, extended operation to 40K Ohms
Control Power Consumption: 3VA @ 120VAC, 3VA @ 24VAC
Input Supply Voltage: 120VAC, 24VAC*

LTA-2 Model
Max. Pressures Hot Water: 250 psi (17.6 kg/cm2) @250˚F (121˚C)
Max. Ambient Temp.: 150˚F (66˚C)
Probe Sensitivity: 20K Ohms, extended operation to 40K Ohms
Control Power Consumption: 2.8VA @ 120VAC, 2.8VA @ 24VAC
Input Supply Voltage: 120VAC, 24VAC*

LTR Model
Max. Pressures Hot Water: 160 psi (11.2 kg/cm2) @250˚F (121˚C)
Max. Ambient Temp.: 120˚F (49˚C)
Probe Sensitivity: 20K Ohms, extended operation to 40K Ohms
Control Power Consumption: 1.5VA @ 120VAC, 1.5VA @ 24VAC
Input Supply Voltage: 24VAC*

*24VAC supplied by a Class 2 power source

Features
  • Probe Style Low Water Cutoff
  • Worry Free Operation
  • Simplified Installation & Wiring
  • LED Verification
  • Selection Ease
  • Seamless Integration
Applications
  • Hot Water Heating Systems
  • Closed Cooling Circuits
  • Air Conditioning Systems
  • Hydronic Heating & Cooling
  • Water/Glycol concentrations up to 50%
  • Solar / Geothermal

The Taco Low Water Cutoff (LWCO) provides accurate and dependable protection for all types of boilers, from small residential hot water boilers to large industrial steam units. The LWCO is a probe-style, microprocessor-based control that detects the fluid level in hot water and steam boilers and reacts when the level falls below the minimum safe operating level specified by the boiler manufacturer.

The Taco LWCO can act as either the primary or secondary low water cutoff on low-pressure steam boilers, the primary limit control on hot water boilers or to protect pumps from running dry in condensate receiver tank applications. The LWCO can also activate alarm systems or automatic water feeders.

Features include:
  • Patented Adjustable Probe Sensitivity
  • External LEDs and Simplified Wiring for Easy Installation and Testing
  • Automatic or Manual Reset Mode
  • Available in 24 VAC or 120 VAC
  • Standard On-Board (NEMA 1) or Remote (NEMA 4) Probe 1/2 or 3/4 NPT Connection
  • LT Models Include External Test Button, Adjustable Delay On Break (DOB) and Delay or Make (DOM) Features