The LC1K0910U7 Schneider Electric (Square D) 240V 20A 3P Mini Contactor is a compact and reliable contactor designed for industrial applications. It features a voltage rating of 240V and a current rating of 20A, making it suitable for a variety of electrical systems. The 3-pole design provides reliable control of three-phase motors and other electrical loads. The contactor is housed in a durable plastic enclosure for protection against dust and moisture. It has a compact design that allows for easy mounting in tight spaces. The LC1K0910U7 is a contactor suitable for various industrial applications requiring reliable and efficient control of electrical loads. Our HVAC supply store offers the best prices and fast shipping for all your industrial supply needs. LC1K0910U7 is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 240V 50/60Hz AC coil and 1NO auxiliary contact. LC1K0910U7 is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 4kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it includes a 240V 50/60Hz AC coil and 1NO built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 45mm wide, for DIN-rail and panel mounting. Provides a control circuit compatible with 50Hz and 60Hz supplies and 1NO built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).
Specifications
- range
- TeSys
- Product or Component Type
- Contactor
- product name
- TeSys K
- Device Application
- Control
- contactor application
- Resistive load;Motor control
- utilisation category
- AC-4;AC-1;AC-3;AC-3e
- poles description
- 3P
- power pole contact composition
- 3 NO
- [Ie] rated operational current
- 20 A 122 °F (50 °C)) <= 440 V AC AC-1 power circuit;9 A<= 440 V AC AC-3 power circuit;16 A 158 °F (70 °C)) 690 V AC AC-1 power circuit;9 A<= 440 V AC AC-3e power circuit
- control circuit type
- AC 50/60 Hz
- [Uc] control circuit voltage
- 230...240 V AC 50/60 Hz
- motor power kW
- 2.2 kW 220...230 V AC 50/60 Hz AC-3;4 kW 380...415 V AC 50/60 Hz AC-3;4 kW 440 V AC 50/60 Hz AC-3;4 kW 480 V AC 50/60 Hz AC-3;4 kW 500...600 V AC 50/60 Hz AC-3;4 kW 660...690 V AC 50/60 Hz AC-3;2.2 kW 400 V AC 50/60 Hz AC-4;2.2 kW 220...230 V AC 50/60 Hz AC-3e;4 kW 380...415 V AC 50/60 Hz AC-3e;4 kW 440 V AC 50/60 Hz AC-3e;4 kW 480 V AC 50/60 Hz AC-3e;4 kW 500...600 V AC 50/60 Hz AC-3e;4 kW 660...690 V AC 50/60 Hz AC-3e
- auxiliary contact composition
- 1 NO
- overvoltage category
- III
- [Ith] conventional free air thermal current
- 20 A 122 °F (50 °C) power circuit;10 A 122 °F (50 °C) signalling circuit
- Irms rated making capacity
- 110 A AC power circuit NF C 63-110;110 A AC power circuit IEC 60947;110 A AC signalling circuit IEC 60947
- rated breaking capacity
- 110 A 415 V IEC 60947;110 A 440 V IEC 60947;80 A 500 V IEC 60947;110 A 220...230 V IEC 60947;110 A 380...400 V IEC 60947;70 A 660...690 V IEC 60947
- associated fuse rating
- 25 A gG <= 440 V power circuit;25 A aM power circuit;10 A gG signalling circuit IEC 60947;10 A gG signalling circuit VDE 0660
- average impedance
- 3 mOhm - Ith 20 A 50 Hz power circuit
- insulation resistance
- > 10 MOhm signalling circuit
- inrush power in VA
- 30 VA 68 °F (20 °C))
- hold-in power consumption in VA
- 4.5 VA 68 °F (20 °C))
- heat dissipation
- 1.3 W
- control circuit voltage limits
- Operational 0.85...1.1 Uc 122 °F (50 °C));Drop-out 0.2...0.75 Uc 122 °F (50 °C))
- maximum operating rate
- 3600 cyc/h
- auxiliary contacts type
- Instantaneous 1 NO
- signalling circuit frequency
- <= 400 Hz
- minimum switching current
- 5 mA signalling circuit
- minimum switching voltage
- 17 V signalling circuit
- operating time
- 10...20 ms coil de-energisation and NO opening;10...20 ms coil energisation and NO closing
- safety reliability level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- non overlap distance
- 0.02 in (0.5 mm)
- mechanical robustness
- Shocks contactor closed;on X axis10 Gn for 11 ms IEC 60068-2-27;Shocks contactor closed;on Y axis15 Gn for 11 ms IEC 60068-2-27;Shocks contactor closed;on Z axis15 Gn for 11 ms IEC 60068-2-27;Shocks contactor opened;on X axis6 Gn for 11 ms IEC 60068-2-27;Shocks contactor opened;on Y axis10 Gn for 11 ms IEC 60068-2-27;Shocks contactor opened;on Z axis10 Gn for 11 ms IEC 60068-2-27;Vibrations contactor closed4 Gn;5...300 Hz IEC 60068-2-6;Vibrations contactor opened2 Gn;5...300 Hz IEC 60068-2-6
- Product Certifications
- CSA;UL;UKCA
- protective treatment
- TC IEC 60068;TC DIN 50016
- operating altitude
- 6561.68 ft (2000 m) without derating
- flame retardance
- V1 conforming to UL 94;Requirement 2 conforming to NF F 16-101;Requirement 2 conforming to NF F 16-102
- Category
- 22326-CTR;K-LINE;AC;OPEN;NONREV
- Discount Schedule
- I12
- GTIN
- 3389110490343
- Returnability
- Yes
- Country of origin
- ID
- Unit Type of Package 1
- PCE
- Number of Units in Package 1
- 1
- Package 1 Height
- 2.56 in (6.5 cm)
- Package 1 Width
- 2.44 in (6.2 cm)
- Package 1 Length
- 1.89 in (4.8 cm)
- Package 1 Weight
- 6.38 oz (181.0 g)
- Unit Type of Package 2
- S02
- Number of Units in Package 2
- 50
- Package 2 Height
- 5.91 in (15 cm)
- Package 2 Width
- 11.81 in (30 cm)
- Package 2 Length
- 15.75 in (40 cm)
- Package 2 Weight
- 20.65 lb(US) (9.368 kg)
- Package 3 Height
- 30.31 in (77 cm)
- Warranty
- 18 months
Reviews
Recently Viewed
New Arrivals
R46930-001 | Ind Mtr Assy 1/20hp 208-230v | Armstrong Furnace
Brand: Armstrong Furnace
SKU: R46930-001
123449 | Exhaust Temperature Sensor | AERCO Boiler and Water Heater
Brand: AERCO Boiler and Water Heater
SKU: 123449
8105-064-0148BX | 230v 1/3hp Var Spd Prog Motor | Bard HVAC
Brand: Bard HVAC
SKU: 8105-064-0148BX
Y2162 | Foam Filter (2-Pack) | Lennox
Brand: Lennox
SKU: Y2162
VA-921-VDC-8 | HUMIDITY SENSOR | MAMAC Systems
Brand: MAMAC Systems
SKU: VA-921-VDC-8
U41001539 | Pump | Mitsubishi Electric
Brand: Mitsubishi Electric
SKU: U41001539People Also Searched
LC1K0910U7
Schneider Electric (Square D) LC1K0910U7
LC1K0910U7 price
Schneider Electric (Square D) LC1K0910U7 price