ATV212HD55N4 | VFD 75HP 380/480VAC 3P IP20 | Schneider Electric (Square D)
$5,813.38
Get your Special Pricing!
Log In / Create an Account for the LOWEST PRICING on our most Popular Brands!
Brand: Schneider Electric (Square D)SKU: ATV212HD55N4
Get a Quote
Availability: Get a Quote

Speak With a Technical Expert

Call (847) 773-1023

Hours: 9am - 4pm CDT M-F

ATV212HD55N4 | VFD 75HP 380/480VAC 3P IP20 | Schneider Electric (Square D)

Schneider Electric (Square D) | ATV212HD55N4
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to ATV212HD55N4

Documents and manuals

Schneider Electric (Square D) ATV212HD55N4 Documents

Overview

Details for ATV212HD55N4

Control Your Industrial Processes with Schneider Electric's ATV212HD55N4 VFD The Schneider Electric (Square D) ATV212HD55N4 Variable Frequency Drive (VFD) grants you precise control over your industrial processes. Engineered for heavy-duty applications, this VFD offers exceptional performance and reliability. Built to withstand harsh environments, the ATV212HD55N4 boasts an IP20 enclosure rating. Its advanced features include input/output expansion capabilities, Modbus communication, and a built-in PLC, providing flexibility and seamless integration. With a power rating of 75HP, 380/480VAC, and 3-phase operation, the ATV212HD55N4 delivers ample power to drive demanding machinery. Its compact design allows for efficient space utilization, making it suitable for various applications. Maximize efficiency, improve performance, and enhance the reliability of your industrial processes with the Schneider Electric (Square D) ATV212HD55N4 VFD. Partner with our HVAC supply store to get the best prices and fast shipping on all your industrial essentials. This Altivar 212 variable speed drive can feed 3-phase asynchronous motors. Its protection index is IP21 and it has a built-in EMC filter. It works at a rated power up to 55kW / 75hp and a rated voltage from 380V to 480V AC. Its design is based on eco-energy with a reduction in energy consumption of up to 70% compared to a conventional control system. Thanks to its cable temperature rise reduction technology, the Altivar 212 drive offers immediate, disturbance-free operation avoiding additional options such as a line choke or DC choke to deal with current harmonics. It weighs 55.4kg and its dimensions are, 320mm wide, 630mm high, 290mm deep. It is specifically designed for the most common fluid management applications in tertiary sector buildings (HVAC) like heating, ventilation, air conditioning and pumping. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions). It is also CE, UL, CSA, C-Tick and NOM certified. The Altivar 212 offers optional motor chokes which can increase the maximum cable lengths between the drive and the motor and limit disturbance at the motor terminals. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. The Altivar 212 drive can easily be adapted to all building management systems thanks to its numerous functions and communication protocols integrated as standard, Modbus, METASYS N2, APOGEE FLN P1 and BACnet. It is eco-friendly and complies with directives such as RoHS, WEEE, etc.relating to environmental protection.
device short name
ATV212
product destination
Asynchronous motors
Phase
3 phase
motor power kW
55 kW
Maximum Horse Power Rating
75 hp
supply voltage limits
323…528 V
supply frequency
50...60 Hz - 5...5 %
line current
102.7 A 380 V;89 A 480 V
Range of Product
Altivar 212
Product or Component Type
Variable speed drive
Product Specific Application
Pumps and fans in HVAC
communication port protocol
METASYS N2;BACnet;LonWorks;APOGEE FLN;Modbus
[Us] rated supply voltage
380...480 V - 15...10 %
EMC filter
Class C2 EMC filter integrated
IP degree of protection
IP21
apparent power
76.3 kVA 380 V
continuous output current
116 A 380 V;116 A 460 V
maximum transient current
127.6 A 60 s
speed drive output frequency
0.5…200 Hz
speed range
1…10
speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
local signalling
for DC bus energized 1 LED (red)
output voltage
<= power supply voltage
isolation
Electrical between power and control
type of cable
Without mounting kit 1 IEC cable 113 °F (45 °C);copper 90 °C / XLPE/EPR;Without mounting kit 1 IEC cable 113 °F (45 °C);copper 70 °C / PVC;With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C);copper 75 °C / PVC
electrical connection
VIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES terminal 0.00 in² (2.5 mm²) / AWG 14;L1/R;L2/S;L3/T terminal 0.23 in² (150 mm²) 300 kcmil)
tightening torque
5.31 lbf.in (0.6 N.m) VIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES);362.88 lbf.in (41 N.m);360 lb.in L1/R;L2/S;L3/T)
supply
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %;<10 A overload and short-circuit protection;Internal supply 24 V DC 21…27 V);<200 A overload and short-circuit protection
sampling duration
2 ms +/- 0.5 ms F discrete;2 ms +/- 0.5 ms R discrete;2 ms +/- 0.5 ms RES discrete;3.5 ms +/- 0.5 ms VIA analog;22 ms +/- 0.5 ms VIB analog
response time
FM 2 ms +/- 0.5 ms analog;FLA;FLC 7 ms +/- 0.5 ms discrete;FLB;FLC 7 ms +/- 0.5 ms discrete;RY;RC 7 ms +/- 0.5 ms discrete
accuracy
+/- 0.6 % VIA) for a temperature variation 60 °C;+/- 0.6 % VIB) for a temperature variation 60 °C;+/- 1 % FM) for a temperature variation 60 °C
linearity error
VIA +/- 0.15 % of maximum value input;VIB +/- 0.15 % of maximum value input;FM +/- 0.2 % output
analogue output type
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits;FM switch-configurable current 0...20 mA 970 Ohm 10 bits
discrete output type
Configurable relay logic FLA;FLC) NO - 100000 cycles;Configurable relay logic FLB;FLC) NC - 100000 cycles;Configurable relay logic RY;RC) NO - 100000 cycles
minimum switching current
3 mA 24 V DC configurable relay logic
maximum switching current
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL;R);5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL;R);2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL;R);2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL;R)
discrete input type
F programmable 24 V DC level 1 PLC 4700 Ohm;R programmable 24 V DC level 1 PLC 4700 Ohm;RES programmable 24 V DC level 1 PLC 4700 Ohm
discrete input logic
Positive logic (source) F;R;RES);<= 5 V;>= 11 V;Negative logic (sink) F;R;RES);>= 16 V;<= 10 V
dielectric strength
3535 V DC between earth and power terminals;5092 V DC between control and power terminals
insulation resistance
>= 1 mOhm 500 V DC for 1 minute
frequency resolution
Display unit 0.1 Hz;Analog input 0.024/50 Hz
Communication Service
Time out setting from 0.1 to 100 s;Write multiple registers (16) 2 words maximum;Write single register (06);Read holding registers (03) 2 words maximum;Read device identification (43);Monitoring inhibitable
option card
Communication card LonWorks
power dissipation in W
1455 W
air flow
131560.04 Gal/hr(US) (498 m3/h)
functionality
Mid
specific application
HVAC
Variable speed drive application selection
Building - HVAC Compressor for scroll;Building - HVAC Fan;Building - HVAC Pump
Motor power range AC-3
55…100 kW 380…440 V 3 phase;55…100 kW 480…500 V 3 phase
motor starter type
Variable speed drive
discrete output number
2
analogue input number
2
analogue input type
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable PTC probe 0...6 probes 1500 Ohm;VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
analogue output number
1
physical interface
2-wire RS 485
Connector Type
1 open style;1 RJ45
Transmission Rate
9600 bps or 19200 bps
transmission frame
RTU
number of addresses
1…247
data format
8 bits;1 stop;odd even or no configurable parity
type of polarization
No impedance
asynchronous motor control profile
Voltage/frequency ratio;automatic IR compensation (U/f + automatic Uo);Flux vector control without sensor;standard;Voltage/frequency ratio;5 points;Voltage/frequency ratio - Energy Saving;quadratic U/f;Voltage/frequency ratio;2 points
torque accuracy
+/- 15 %
transient overtorque
120 % of nominal motor torque +/- 10 % 60 s
acceleration and deceleration ramps
Automatic based on the load;Linear adjustable separately from 0.01 to 3200 s
motor slip compensation
Adjustable;Automatic whatever the load;Not available in voltage/frequency ratio motor control
switching frequency
6...16 kHz adjustable;8...16 kHz with derating factor
nominal switching frequency
8 kHz
braking to standstill
By DC injection
Network Frequency
47.5...63 Hz
prospective line Isc
22 kA
protection type
Overheating protection drive;Thermal power stage drive;Short-circuit between motor phases drive;Input phase breaks drive;Overcur

Specifications

Item Number
ATV212HD55N4
Brand
Schneider Electric (Square D)
Brand
Schneider Electric (Square D)
device short name
ATV212
product destination
Asynchronous motors
Phase
3 phase
motor power kW
55 kW
Maximum Horse Power Rating
75 hp
supply voltage limits
323…528 V
supply frequency
50...60 Hz - 5...5 %
line current
102.7 A 380 V;89 A 480 V
Range of Product
Altivar 212
Product or Component Type
Variable speed drive
Product Specific Application
Pumps and fans in HVAC
communication port protocol
METASYS N2;BACnet;LonWorks;APOGEE FLN;Modbus
[Us] rated supply voltage
380...480 V - 15...10 %
EMC filter
Class C2 EMC filter integrated
IP degree of protection
IP21
apparent power
76.3 kVA 380 V
continuous output current
116 A 380 V;116 A 460 V
maximum transient current
127.6 A 60 s
speed drive output frequency
0.5…200 Hz
speed range
1…10
speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
local signalling
for DC bus energized 1 LED (red)
output voltage
<= power supply voltage
isolation
Electrical between power and control
type of cable
Without mounting kit 1 IEC cable 113 °F (45 °C);copper 90 °C / XLPE/EPR;Without mounting kit 1 IEC cable 113 °F (45 °C);copper 70 °C / PVC;With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C);copper 75 °C / PVC
electrical connection
VIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES terminal 0.00 in² (2.5 mm²) / AWG 14;L1/R;L2/S;L3/T terminal 0.23 in² (150 mm²) 300 kcmil)
tightening torque
5.31 lbf.in (0.6 N.m) VIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES);362.88 lbf.in (41 N.m);360 lb.in L1/R;L2/S;L3/T)
supply
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %;<10 A overload and short-circuit protection;Internal supply 24 V DC 21…27 V);<200 A overload and short-circuit protection
sampling duration
2 ms +/- 0.5 ms F discrete;2 ms +/- 0.5 ms R discrete;2 ms +/- 0.5 ms RES discrete;3.5 ms +/- 0.5 ms VIA analog;22 ms +/- 0.5 ms VIB analog
response time
FM 2 ms +/- 0.5 ms analog;FLA;FLC 7 ms +/- 0.5 ms discrete;FLB;FLC 7 ms +/- 0.5 ms discrete;RY;RC 7 ms +/- 0.5 ms discrete
accuracy
+/- 0.6 % VIA) for a temperature variation 60 °C;+/- 0.6 % VIB) for a temperature variation 60 °C;+/- 1 % FM) for a temperature variation 60 °C
linearity error
VIA +/- 0.15 % of maximum value input;VIB +/- 0.15 % of maximum value input;FM +/- 0.2 % output
analogue output type
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits;FM switch-configurable current 0...20 mA 970 Ohm 10 bits
discrete output type
Configurable relay logic FLA;FLC) NO - 100000 cycles;Configurable relay logic FLB;FLC) NC - 100000 cycles;Configurable relay logic RY;RC) NO - 100000 cycles
minimum switching current
3 mA 24 V DC configurable relay logic
maximum switching current
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL;R);5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL;R);2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL;R);2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL;R)
discrete input type
F programmable 24 V DC level 1 PLC 4700 Ohm;R programmable 24 V DC level 1 PLC 4700 Ohm;RES programmable 24 V DC level 1 PLC 4700 Ohm
discrete input logic
Positive logic (source) F;R;RES);<= 5 V;>= 11 V;Negative logic (sink) F;R;RES);>= 16 V;<= 10 V
dielectric strength
3535 V DC between earth and power terminals;5092 V DC between control and power terminals
insulation resistance
>= 1 mOhm 500 V DC for 1 minute
frequency resolution
Display unit 0.1 Hz;Analog input 0.024/50 Hz
Communication Service
Time out setting from 0.1 to 100 s;Write multiple registers (16) 2 words maximum;Write single register (06);Read holding registers (03) 2 words maximum;Read device identification (43);Monitoring inhibitable
option card
Communication card LonWorks
power dissipation in W
1455 W
air flow
131560.04 Gal/hr(US) (498 m3/h)
functionality
Mid
specific application
HVAC
Variable speed drive application selection
Building - HVAC Compressor for scroll;Building - HVAC Fan;Building - HVAC Pump
Motor power range AC-3
55…100 kW 380…440 V 3 phase;55…100 kW 480…500 V 3 phase
motor starter type
Variable speed drive
discrete output number
2
analogue input number
2
analogue input type
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable PTC probe 0...6 probes 1500 Ohm;VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
analogue output number
1
physical interface
2-wire RS 485
Connector Type
1 open style;1 RJ45
Transmission Rate
9600 bps or 19200 bps
transmission frame
RTU
number of addresses
1…247
data format
8 bits;1 stop;odd even or no configurable parity
type of polarization
No impedance
asynchronous motor control profile
Voltage/frequency ratio;automatic IR compensation (U/f + automatic Uo);Flux vector control without sensor;standard;Voltage/frequency ratio;5 points;Voltage/frequency ratio - Energy Saving;quadratic U/f;Voltage/frequency ratio;2 points
torque accuracy
+/- 15 %
transient overtorque
120 % of nominal motor torque +/- 10 % 60 s
acceleration and deceleration ramps
Automatic based on the load;Linear adjustable separately from 0.01 to 3200 s
motor slip compensation
Adjustable;Automatic whatever the load;Not available in voltage/frequency ratio motor control
switching frequency
6...16 kHz adjustable;8...16 kHz with derating factor
nominal switching frequency
8 kHz
braking to standstill
By DC injection
Network Frequency
47.5...63 Hz
prospective line Isc
22 kA
protection type
Overheating protection drive;Thermal power stage drive;Short-circuit between motor phases drive;Input phase breaks drive;Overcur
device short name
ATV212
product destination
Asynchronous motors
Phase
3 phase
motor power kW
55 kW
Maximum Horse Power Rating
75 hp
supply voltage limits
323…528 V
supply frequency
50...60 Hz - 5...5 %
line current
102.7 A 380 V;89 A 480 V
Range of Product
Altivar 212
Product or Component Type
Variable speed drive
Product Specific Application
Pumps and fans in HVAC
communication port protocol
METASYS N2;BACnet;LonWorks;APOGEE FLN;Modbus
[Us] rated supply voltage
380...480 V - 15...10 %
EMC filter
Class C2 EMC filter integrated
IP degree of protection
IP21
apparent power
76.3 kVA 380 V
continuous output current
116 A 380 V;116 A 460 V
maximum transient current
127.6 A 60 s
speed drive output frequency
0.5…200 Hz
speed range
1…10
speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
local signalling
for DC bus energized 1 LED (red)
output voltage
<= power supply voltage
isolation
Electrical between power and control
type of cable
Without mounting kit 1 IEC cable 113 °F (45 °C);copper 90 °C / XLPE/EPR;Without mounting kit 1 IEC cable 113 °F (45 °C);copper 70 °C / PVC;With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C);copper 75 °C / PVC
electrical connection
VIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES terminal 0.00 in² (2.5 mm²) / AWG 14;L1/R;L2/S;L3/T terminal 0.23 in² (150 mm²) 300 kcmil)
tightening torque
5.31 lbf.in (0.6 N.m) VIA;VIB;FM;FLA;FLB;FLC;RY;RC;F;R;RES);362.88 lbf.in (41 N.m);360 lb.in L1/R;L2/S;L3/T)
supply
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %;<10 A overload and short-circuit protection;Internal supply 24 V DC 21…27 V);<200 A overload and short-circuit protection
sampling duration
2 ms +/- 0.5 ms F discrete;2 ms +/- 0.5 ms R discrete;2 ms +/- 0.5 ms RES discrete;3.5 ms +/- 0.5 ms VIA analog;22 ms +/- 0.5 ms VIB analog
response time
FM 2 ms +/- 0.5 ms analog;FLA;FLC 7 ms +/- 0.5 ms discrete;FLB;FLC 7 ms +/- 0.5 ms discrete;RY;RC 7 ms +/- 0.5 ms discrete
accuracy
+/- 0.6 % VIA) for a temperature variation 60 °C;+/- 0.6 % VIB) for a temperature variation 60 °C;+/- 1 % FM) for a temperature variation 60 °C
linearity error
VIA +/- 0.15 % of maximum value input;VIB +/- 0.15 % of maximum value input;FM +/- 0.2 % output
analogue output type
FM switch-configurable voltage 0...10 V DC 7620 Ohm 10 bits;FM switch-configurable current 0...20 mA 970 Ohm 10 bits
discrete output type
Configurable relay logic FLA;FLC) NO - 100000 cycles;Configurable relay logic FLB;FLC) NC - 100000 cycles;Configurable relay logic RY;RC) NO - 100000 cycles
minimum switching current
3 mA 24 V DC configurable relay logic
maximum switching current
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL;R);5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL;R);2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL;R);2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL;R)
discrete input type
F programmable 24 V DC level 1 PLC 4700 Ohm;R programmable 24 V DC level 1 PLC 4700 Ohm;RES programmable 24 V DC level 1 PLC 4700 Ohm
discrete input logic
Positive logic (source) F;R;RES);<= 5 V;>= 11 V;Negative logic (sink) F;R;RES);>= 16 V;<= 10 V
dielectric strength
3535 V DC between earth and power terminals;5092 V DC between control and power terminals
insulation resistance
>= 1 mOhm 500 V DC for 1 minute
frequency resolution
Display unit 0.1 Hz;Analog input 0.024/50 Hz
Communication Service
Time out setting from 0.1 to 100 s;Write multiple registers (16) 2 words maximum;Write single register (06);Read holding registers (03) 2 words maximum;Read device identification (43);Monitoring inhibitable
option card
Communication card LonWorks
power dissipation in W
1455 W
air flow
131560.04 Gal/hr(US) (498 m3/h)
functionality
Mid
specific application
HVAC
Variable speed drive application selection
Building - HVAC Compressor for scroll;Building - HVAC Fan;Building - HVAC Pump
Motor power range AC-3
55…100 kW 380…440 V 3 phase;55…100 kW 480…500 V 3 phase
motor starter type
Variable speed drive
discrete output number
2
analogue input number
2
analogue input type
VIA switch-configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable voltage 0...10 V DC 24 V max 30000 Ohm 10 bits;VIB configurable PTC probe 0...6 probes 1500 Ohm;VIA switch-configurable current 0...20 mA 250 Ohm 10 bits
analogue output number
1
physical interface
2-wire RS 485
Connector Type
1 open style;1 RJ45
Transmission Rate
9600 bps or 19200 bps
transmission frame
RTU
number of addresses
1…247
data format
8 bits;1 stop;odd even or no configurable parity
type of polarization
No impedance
asynchronous motor control profile
Voltage/frequency ratio;automatic IR compensation (U/f + automatic Uo);Flux vector control without sensor;standard;Voltage/frequency ratio;5 points;Voltage/frequency ratio - Energy Saving;quadratic U/f;Voltage/frequency ratio;2 points
torque accuracy
+/- 15 %
transient overtorque
120 % of nominal motor torque +/- 10 % 60 s
acceleration and deceleration ramps
Automatic based on the load;Linear adjustable separately from 0.01 to 3200 s
motor slip compensation
Adjustable;Automatic whatever the load;Not available in voltage/frequency ratio motor control
switching frequency
6...16 kHz adjustable;8...16 kHz with derating factor
nominal switching frequency
8 kHz
braking to standstill
By DC injection
Network Frequency
47.5...63 Hz
prospective line Isc
22 kA
protection type
Overheating protection drive;Thermal power stage drive;Short-circuit between motor phases drive;Input phase breaks drive;Overcur

Reviews

People Also Searched

ATV212HD55N4
Schneider Electric (Square D) ATV212HD55N4
ATV212HD55N4 price
Schneider Electric (Square D) ATV212HD55N4 price