Get your Special Pricing!
ULSS-10 | 4.1' (1.25 m) measuring range | non-contact transmitter | SPST programmable relays | 1" NPT thread.(USB adapter necessary for calibration. One adapter can program multiple units.) | Dwyer Instruments
The photo is for representation purposes only and may not be a photo of product being purchased.
Search products similar to ULSS-10
Documents and manuals
Dwyer Instruments ULSS-10 Documents
Overview
Details for ULSS-10
Dwyer Instruments ULSS-10 Ultrasonic Level Sensor: Precision Liquid Level Measurement
The ULSS-10 Ultrasonic Level Sensor from Dwyer Instruments provides accurate and reliable continuous level measurement of liquids in tanks, sumps, and reservoirs. Engineered with advanced ultrasonic technology, this non-contact sensor offers exceptional performance for a wide range of industrial applications.
Key Features:
• Non-contact ultrasonic technology for accurate level measurement without contact with the liquid
• 1" NPT process connection for easy installation
• 4-20 mA output for straightforward integration with control systems
• Compact and lightweight design for space-saving installation
• IP67-rated housing for protection against dust and water ingress
Benefits:
• Continuous level monitoring for optimal process control and inventory management
• Non-invasive measurement eliminates contamination risks and maintenance downtime
• Accurate and reliable data for informed decision-making
• Robust construction for long-lasting performance in harsh environments
Applications:
• Chemical and petrochemical industries
• Water and wastewater treatment plants
• Food and beverage processing
• Pharmaceutical manufacturing
• Power generation facilities
Shop our HVAC supply store for the most competitive prices and fast shipping on the ULSS-10 Ultrasonic Level Sensor from Dwyer Instruments. Trust our expertise for all your industrial supply needs.
MODEL ULSS ULTRASONIC LEVEL SENSOR
4.1' (1.25 m) Measuring Range, Non-Contact Transmitter, SPST Programmable Relays
The Model ULSS Ultrasonic Level Sensor provides non-contact, continuous ultrasoniclevel measurement of fluids for short range applications. Ultrasonic technology paired withautomatic temperature compensation provides accurate and reliable measurements inalmost all conditions. The Model ULSS has failsafe logic that is easily configured to customapplications via free software removing the need for target calibration. Using the freesoftware, the Model ULSS can be programmed to transmit an output signal as well as setthe four relays for control applications. This rugged design comes with a NEMA 6Psubmersible enclosure rating to ensure a long lasting unit.
Product Applications
- Water and wastewater
- Pulp and paper processing
- Sump and process tanks
- Chemical processing
- Food and beverage
- Has a 4.1´ (1.2 m) measuring range with a 0.125" (3 mm) accuracy
- Via free software, units can be programmed to transmit an output signal and operatefour relays for control applications
- Provides reliable, accurate, and non-contact level measurement of compatibleliquids
- Non-contact technology offers no moving parts to wear, jam, corrode, or get coatedlike contact technologies
- Mapping software makes effective measuring surface only a 3" (76.2 mm) diametercolumn with no concerns of ladders, pipes, or other tank intrusions in the remainingsound cone
- Ultrasonic technology paired with automatic temperature compensation providesaccurate and reliable measurements in almost all conditions
- Fail-safe logic is easily configured to custom applications via free software removingthe need for target calibration
- Full NEMA 6P submersible enclosure rating to ensure excellent product durability
Specifications
- Service
- Compatible fluids.
- Wetted Materials
- Sensor: PVDF; O-ring: FKM.
- Ranges
- 4.1' (1.25 m).
- Accuracy
- 0.125" (3 mm).
- Resolution
- 0.019" (0.5 mm).
- Blind Zone
- 2" (5 cm).
- Beam Width
- 2" (5 cm).
- Temperature Limits
- Process: 20 to 140°F (-7 to 60°C);Ambient: -31 to 140°F (-35 to 60°C).
- Temperature Compensation
- Automatic.
- Pressure Limit
- 30 psi (2 bar).
- Power Requirement
- 12 to 28 VDC.
- Output Signal
- 4 to 20 mA; 2-wire;Invert: 4 to 20 mA or 20 to 4 mA;Fail-safe: 4 mA; 20 mA; 21 mA; 22 mA; or hold last.
- Loop Resistance
- 400 Ω max.
- Electrical Connections
- 4' (1.2 m) 9 conductor shielded cable.
- Contact Type
- 4 SPST relays.
- Contact Rating
- 1 A max @ 28 VDC max.
- Deadband
- Selectable (no hysteresis; 1/4"; 1/2"; 1"; 1/2 cm; 1 cm; 2 cm; 5 cm ornot available).
- Process Connection
- 1" NPT; 1" BSPP (optional).
- Enclosure Rating
- NEMA 6P (IP68).
- Enclosure Material
- Polycarbonate; Gland: TPE.
- Mounting Orientation
- Vertical.
- Memory
- Non-volatile.
- Failsafe
- Contact: Power loss: Holds Last contact;Power on: Open; close; or last contact.
- Programming
- Free PC software download (USB adapter required).
- Weight
- 1 lb (0.45 kg).
- Agency Approvals
- CE.